Sign In | Join Free | My portofva.com |
|
Categories | Electronic Weighing Indicator |
---|---|
Brand Name: | Supmeter |
Model Number: | BST106-B11 |
Certification: | CE |
Place of Origin: | China |
MOQ: | 1pcs |
Price: | Negotiation |
Payment Terms: | T/T, Western Union |
Supply Ability: | 1000pcs/month |
Delivery Time: | 1-20 working days |
Packaging Details: | 1pcs/box |
Power Supply: | AC220V |
DI: | 3 |
DO: | 4 |
AO: | 1 |
Communication: | RS232 |
Material Level Weighing Controller Electronic Weighing Indicator For Material Level Scale, Hopper Scale & Platform Scale
Picture
Model LED Panel-mounting Operation Interface
If there is not any keypad operation in one minute and it’s not in
the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’,
the controller will return to ‘Main Display Interface’
automatically.
Menu Operation | |
Key Name | Description |
【MENU】 | Enter Main Menu. Exit. Keep it pressed for 2 seconds: Key-locking / Key-unlocking. |
【ENT】 | Enter/Save/Alarm Acknowledge. |
【◄】 | Cursor shifts left. |
【►】 | Cursor shifts right. |
【▲】 | Display the previous option. |
【▼】 | Display the next option. |
Quick Operation | |
【G/N】 | APL0 Hopper Weighing Mode: Gross Weight / Net Weight display switch. |
APL1 Ration Feeding/Batching Mode: Gross Weight / Net Weight / Feeding Weight display Switch.
| |
【ZERO】 |
|
【TARE】 |
|
【CAL】 |
|
【▲】【▼】* | * Keep it pressed for 2 seconds: Setpoint parameters setting. |
【PRINT】 | Print Weighing/Batching Report. |
Model Panel-mounting Installation
Hopper Weighing Mode :
Parameter Setting: [110]APPL=1, [209]APL0=1, 2 or 3.
![]() |