Sign In | Join Free | My portofva.com |
|
Categories | Smoke Alarm Detector |
---|---|
Brand Name: | ARIZA |
Model Number: | SM11R |
Certification: | TUV CE |
Place of Origin: | GuangDong China |
MOQ: | 500PCS |
Price: | $12.12-$12.9 |
Payment Terms: | T/T, Western Union |
Supply Ability: | 10000 per day |
Delivery Time: | 7-15 days |
Packaging Details: | Qty:50pcs/ctn Size:39.5*34*32.5cm G.W:10kg/ctn |
Product name: | 85DB Wireless Interconnected Smoke Alarm Detector |
Frequency: | 433.92MHz or 868MHz (Customized) |
Working distance: | Up to 100m (Outdoor open) |
Alarm Volume: | >85 dB(A) at 3 meters |
Alarm Sensitivity: | 0.09 - 0.17 dB/m |
Battery: | 10 years lithium battery |
Interlinked devices:: | Max 30pcs per group |
Operation Current: | <10uA (standby); <70mA (alarm) |
Silence Time: | approx. 10 minutes |
Comply to Standard: | EN14604:2005/AC:2008 |
Ultrathin Home ssafety 85DB Wireless Interconnected Smoke Alarm Detector with self checking
About this item:
1. The Interconnected Wireless Smoke Alarm with Voice Location features an 85-decibel siren that tells you where the danger is located. A photoelectric sensor detects smoke while minimizing false alarms from cooking or shower steam. Interconnected smoke detectors in different locations are designed to work together, with one alarm triggering the other alarm during a fire, helping to provide the earliest warning for your family.
2. Battery powered alarm requires no rewiring for installation and
provides continued monitoring even if there's a power failure
3. Wirelessly connect upto 30 first alert enabled alarms for the
maximum in whole home protection; includes test/silence button, low
battery warning, end of life timer
Specification:
Product name | 433MHZ 868MHZ Wireless Interconnected Smoke Alarm Detector With TUV Approval 10 Years Warranty |
Material | ABS |
Product size | 120*31 mm |
Alarm Volume | >85 dB(A) at 3 meters |
Alarm Sensitivity | 0.09 - 0.17 dB/m |
Battery | 10 years lithium battery |
Low Battery | 2.6 ± 0.1 V |
Operation Current | <10uA (standby); <70mA (alarm) |
Silence Time | approx. 10 minutes |
Comply to Standard | EN14604:2005/AC:2008 |
Frequency | 433.92MHz or 868MHz (Customized) |
Working distance | Up to 100m (Outdoor open) |
Interlinked devices: | Max 30pcs per group |
Feature:
Smarter Wireless Interconnection
Upgraded with advanced wireless interconnection technology, this
smoke alarm uses radio frequency (RF) signals to communicate with
up to 24 alarms. When one alarm is triggered, all alarms will
sound. This allows you to hear an alarm from anywhere in your home,
regardless of where the fire hazard starts, ensuring the safety of
your entire home.
10-Year warranty Battery with Low Battery Warning
The wireless alarm utilizes a 10 years lithium battery that
supports up to 10 years of continuous monitoring. A self-check
function issues a low battery warning - Red LED flashes once every
60
seconds and 1 beep every 60 seconds. - to inform you it’s time to
replace device, ensuring uninterrupted protection for enhanced
safety.
Quickly Locate the Source Alarm
Only the originating unit can silence all interconnected alarms.
Press the test/silence button on any interconnected alarm. If all
alarms are muted, the smoke alarm you pressed is the source alarm.
If one smoke alarm is still sounding, that alarm is the source
alarm. This allows you to easily locate the source alarm, ensuring
an immediate respond to fire.
How to create the interlinked network:
Step 1: Press the test/silence button on one of these smoke alarms
4 times, and the green LED will rapidly flash continuously,
indicating it has entered the transmitting mode (valid time: 60
seconds) .
Step 2: Press the test/silence button on the other smoke alarms
twice, and the green LED will slowly flash continuously, indicating
it has entered the receiving mode.
-----If pairing is successful: The green LED of these alarms will
stop flashing.
-----When it is failure: The green light will continue to flash for
60 seconds, and then the red light will stay on for 2 seconds.
How to disabling the interconnect function:
Press the test/silence button on the smoke alarms twice and the
green LED will slowly flash continuously still 60 seconds, then
ignore it and it will automatic despairing.
How to silence the alarms in network when alarm:
If the smoke alarm detects fire, the device will goes into
Source/Master smoke alarm sound pattern alarmed, and emits the
alarm signal; When other alarm devices received alarm signal, they
will goes into Slave smoke alarm sound pattern, until the
Source/Master alarm device stopped alarm; During the unit is
alarming, you can find out the Source/Master smoke alarm , press
the Test/Silence button to pause all other interconnected alarms.
Package List:
1 × Photoelectric smoke alarm
1 × Mounting bracket
1 × Screw Kit
1 × User manual
Qty:50pcs/ctn
Size:39.5*34*32.5cm
G.W:10kg/ctn
Trouble Shooting:
Probem: The alarm does not sound when testing
1. Please check whether the batteries be well assembled according
to the Guide required
Probem: Red LED flashes and the alarm delivers one beep every 60
seconds
The battery is low.
Probem: The alarm delivers one beep every 40 seconds
1. clean the alarm. please refer to the “maintenance and cleaning”
section.
2. The alarm is malfunctioning. Contact the retailer to replace it.
Probem: Nuisance alarms triggered intermittently or when residents
are cooking, taking showers, etc.
1. Press silence button.
2. Clean the alarm. Please refer to the“maintenance and cleaning”
section.
3. Move the alarm to new location.
![]() |