Sign In | Join Free | My portofva.com |
|
Categories | Fixed Gas Detector |
---|---|
Brand Name: | Zetron |
Model Number: | MIC500S |
Certification: | CE |
Place of Origin: | China |
MOQ: | 1 |
Price: | USD 300-- 1000/set |
Payment Terms: | L/C, D/A, T/T, MoneyGram |
Supply Ability: | 10000 set/month |
Delivery Time: | 3-7 days |
Packaging Details: | paper carton |
Product Name: | Fixed gas detector |
Gas Unit: | PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/l |
Display Method: | 1.7-inch high-definition color screen |
Protection level: | IP65 |
Weight: | 1.8kg |
Size: | 210*170*85mm (L*H*W) |
Company Info. |
Beijing Zetron Technology Co., Ltd |
Verified Supplier |
View Contact Details |
Product List |
MIC500S Fixed Toxic And Harmful Gas Detector
Gases to be detected | Ozone/O3 Gas Detector | ||||
Detection range | 0--1000 ppm 0-- 5000 ppm 0-- 50000ppm 0-- 200mg/L Other ranges can be customized | ||||
Resolution | 0.01ppm or 0.001ppm (0 ~ 10 ppm); 0.001% Vol Other ranges can be customized | ||||
Detection principle | Ultraviolet sensor Electrochemical, infrared, thermal conductivity, PID photoionization, and so on. Depending on the type of gas, range, field environment, and user demand, Sensor can be customized | ||||
Sensor service life | Electrochemical principle: 2 ~ 3 years; Infrared principle: 5 ~ 10 years; Thermal conductivity: 5 years | ||||
Allowable error | ≤±3% F.S (other or higher precision levels can be customized) | ||||
Linearity | ≤±2% | Repeatability | ≤±2% | Uncertainty | ≤±2% |
Response time | T90≤20 seconds | Recovery time | ≤30 seconds | ||
Working environment | Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH (regular) | ||||
Display method | 1.7-inch high-definition color screen | ||||
Working voltage | 12 ~ 30VDC direct current the standard power supply for a single piece of equipment is 24V, DC stabilized voltage switching power supply of 1A or greater than 1A | ||||
Protection level | IP65 | ||||
Explosion-proof type | Explosion suppression type | ||||
Explosion-proof mark | ExdⅡCT6, certificate number: CNEx15.1283 |
①It can be used in 24 hours continuous online monitoring of single
field gas concentration
and the types for detection are more than 500 types.
②There are 7 gas units to display, and the units can be switched
freely.
Units that can be selected: PPM, mg/m3, Vol%, LEL%, PPHM, ppb,
mg/l.
1.7-inch high-definition color screen, display the real-time concentration, and alarm state.
①It is possible for the real-time monitoring via the wired or
remote wireless transmission, and network transmission.
②Three-wire system 4 ~ 20mA standard signal and standard bus RS485
(modbus-RTU) simultaneous output.
③It is possible to select frequency output 200-1000Hz, Hart
protocol signal, 1 ~ 5V output,
two-wire system 4 ~ 20mA, SMS alarm, wireless transmission (2 ~5 km
or unlimited distance).
④It is compatible with secondary instrument, data acquisition
module, PLC, DCS system,
and it is possible to drive the related equipment.
1. Multiple alarm modes, and multi-directional and three-dimensional
indication alarm states.
Alarm types include concentration alarm and failure alarm.
Multiple alarm mode settings: low alarm, high alarm, interval
alarm, and weighted average alarm.
2. Zero-point automatic tracking; long-term use will not be
affected by the zero drift.
3. Multi-level calibration for target points, can ensure the
linearity and accuracy of the measurements.
4. Log recording Record the calibration logs, repair logs, failure
history, failure countermeasure solutions,
sensor service life due to reminder, and function of reminder for
the time of next concentration calibration.
5. Data recovery function; in case of misoperation, it is possible
to select partial or full recovery.
6. Mis-operation recognition function: automatic recognition and
prevention of the concentration calibration misoperation,
which is possible to avoid the poor performance that may be caused
by human factors.
Standard configuration includes the infrared remote control, it is
possible for one-key operation via an infrared remote
control function key, which can achieve the operation without
opening the cover under hazardous situations.
such as the functions like modification of the alarm point, density
calibration, zero-point calibration, noise reduction,
restoring the factory setting, and so on.
■Integrated sound & light alarming device, split-type sound & light
alarming device,
24V DC stabilized voltage power supply.
■Wireless transmission
①It is possible to transfer data wirelessly to the cell phone,
remote monitoring center,
monitoring computers and other monitoring equipment, which will
utilize the upper-level host to realize
the functions of data analysis, storage, printing, or the like on
the computer.
■ Pretreatment system
①Room temperature and high humidity pretreatment system
②High temperature and high humidity pretreatment system
③High temperature high humidity and high dust pretreatment system
■Accessory for connection with a computer for monitoring
①Free upper-level host software, RS485 / RS232 converter
②For laptop without RS232 interface, USB / RS232 converting and
connecting cable is needed,
if the network transmission is needed, TCP / IP converter will be
further needed.
All the cases require the fixed installation, and online detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Q: What is your terms of payment?
A: We accept trade assurance, western union, visa master card, and
tt.
Trade assurance can protect you, when you confirm the product then
the money into my account.
Q: When do you reply to messages?
A: We will reply to your inquiry in 24 hours.
Q: What is the warranty for your product?
A: Warranty: 12 months, Lifetime maintenance
Q: When do you send the products? And how do you send it?
A: For the small order, we will send out the goods within 5 days,
If have stock, we will send it immediately.
We send them by ups, FedEx, TNT, or DHL. For big order, normal is
20 days will finish.
Q: Do you accept OEM or revised logo, color, model, size?
A: Yes, we accept OEM for the qualified buyer. We can make the
products according to customer personal requirements.
Q: How about the quality of the management?
A: We have a complete quality control system, all of our products
will be fully pre-inspection by QC departments before shipping to
you. We have the certification of ISO, CE we could send the
certification test of our company to you.
Q: How about your after-sale service?
A: After sending, we will track the products for you, until you get
the products.
When you got the goods, test them, and give me feedback.
If you have any questions about the problem, contact us, we will
offer the solve way for you.
![]() |