Sign In | Join Free | My portofva.com
portofva.com
Products
Search by Category
Home > Electronic & Instrument Enclosures >

UPS PDU 600W Outdoor Telecom Enclosure Anti Theft Lock With 1.5mm Thickness Plate

Categories Outdoor Telecom Enclosure
Brand Name: ESTEL
Model Number: ET9090135-5
Certification: ISO9001, CE, 3C, FCC, TLC, IP55
Place of Origin: Shenzhen, China (Mainland)
MOQ: 1 SET
Price: Negotiation
Payment Terms: L/C, D/A, D/P, T/T, MoneyGram
Supply Ability: 5,000 sets per month
Delivery Time: 15-20 working days
Packaging Details: Wooden case
Internal Dimension H*W*D: 1050*800*800mm
External Dimension H*W*D: 1350*900*900mm
Cooling: 600W Air Conditioner
Storage Temperature:: -50°C ~ + 70°C
Air Pressure: 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
Fans: DC48V
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

UPS PDU 600W Outdoor Telecom Enclosure Anti Theft Lock With 1.5mm Thickness Plate

UPS PDU 600W Outdoor Telecom Enclosure Anti Theft Lock With 1.5mm Thickness Plate


1. Description Of Outdoor cabinet

this equipment safeguards all the electrical components that it houses from wear and tear, harsh surrounding and theft.You see, acquiring some of these components is often expensive.And that’s the reason protecting them from such elements becomes helpful.You also need this equipment for storing all the relevant electrical parts that you use in the industry.It follows that in many instances, you’ll need quite a number of elements which use electricity.So having all the connections, switches and controls could be somewhat challenging. And that’s why you’d need an Outdoor cabinet to enable you to store all these parts appropriately for easy and effective access.


2. Selling points and Feature Of Outdoor cabinet

● Front door to access the inside equipment

● Anti corrosion outdoor powder coating

● Standard 19“ rack for installation

● High integration, compact structure, easy installation and migration on later stage

● Anti-theft lock, excellent keyhole protection device

● Embedded door, enhance anti-theft


3. Technical Parameters


ItemTypeTechnical Parameter
StructureDimension

External Dimension H*W*D 1350*900*900mm

Internal Dimension H*W*D 1050*800*800mm

LayoutOne compartment
Equipment Installation Method19” standard rack
DoorWith one front door
MaterialGalvanized steel; thickness of the plate: 1.5mm, with heat insulation
StructureAssembled
Ingress ProtectionIP55
Temperature ControlCooling600W Air Conditioner and fans
LightingLED lamp48V LED lamp
TemperatureTemperatureWorking Temperature: -40°C ~ +55°C
Storage Temperature: -50°C ~ + 70°C
Transport Temperature: -50°C ~ +70°C
HumidityRelative Humidity5% ~ 100%
PressureAir Pressure62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
Radiation IntensitySolar Radiation Intensity1124 × (1±5%)W/m2

4. Accessories List

No.ItemQuantityUnitSpecs
1Outdoor Telecom Cabinet1Set

(1)External Dimension H*W*D 1350*900*900mm

Internal Dimension H*W*D 1050*800*800mm

(2) One compartment;

(3) With one front door with special lock for outdoor cabinet (support padlock)

(4) Material: galvanized steel; thickness of the plate: 1.5mm, with heat insulation

2Air Conditioner1Set600W Air Conditioner, AC220V power supply
3110V To 220V Transformer1SetUsed for air conditioner input
4Fans4PC12038, DC48V
5Power Distribution Unit1Set

Grade B Lightning Proof

AC Input: 63A/2P *1;

AC Output: 16A/1P*4;

DC Output: 16A/1P*4.

Height: 4U

6Embedded Telecom Power System (UPS)1Set

DC48V, 60A, 3210W; Model:

1U-4860, Height: 1U.

7Package1SetWooden Case

5. Enclosure Cooling

One set Air conditioner 600W and 4 pcs DC48V fans.


6. Cabinet Structure

(1) External Dimension H*W*D 1350*900*900mm

Internal Dimension H*W*D 1050*800*800mm

(2) One compartment;

(3) With one front door,with special lock for outdoor cabinet (support padlock)

(4) Material: galvanized steel; thickness of the plate: 1.5mm, with heat insulation

7. Air Conditioner

Maintenance Tools:

  • Vacuum cleaner or compressed air cleaning agent
  • Soft brush
  • Cross screwdriver
  • Multimeter
  • Clamp meter
  • Digital thermometer

In order to keep normal temperature environment inside the cabinet, please conduct maintenance according to the “Maintenance Table”.

Maintenance Steps:

  • Turn off the power.
  • Disconnect the power line, and disconnect the signal line.
  • Conduct maintenance according to the “Maintenance Table”.
  • Connect the power line and signal line.
  • Operating testing program.
  • Disconnect the power, restore the normal operating status.
  • Connect the power.
  • The equipment installation should reserve a maintenance space not less than 300mm.