Sign In | Join Free | My portofva.com
portofva.com
Products
Search by Category
Home > Energy Meters >

HANDHELD THREE PHASE POWER QUALITY ANALYZER WITH CLAMP ON CT

Categories Power Quality Analyzer
Place of Origin: Beijing, China
Brand Name: GFUVE
Certification: ISO 9001 : 2008; CE
Model Number: E6000
Accuracy: 0.1%
MOQ: 1SET
Price: USD6000-12000
Packaging Details: Standard export box
Delivery Time: 7days
Payment Terms: T/T, Western Union, Paypal
Supply Ability: 200pcs/month
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    HANDHELD THREE PHASE POWER QUALITY ANALYZER WITH CLAMP ON CT

    E6000 HANDHELD THREE PHASE POWER QUALITY ANALYZER WITH CLAMP ON CT

    E6000 handheld three phase power quality analyzer with CT offer the best ability in power quality analysis, E6000 handheld power quality analyzer help locate, predict, prevent and troubleshoot power quality problems in three phase and single phase power distribution systems. Additionally, GFUVE patented energy loss algorithm, unified power measurement, measuring and counting energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy losses in the system.

    FEATURES

    • 3s statistical interval, continuously record 120h;
    • Support multi-brand current transformer;
    • Up to 8G data storage space;
    • Record up to 461 power energy parameters simultaneously;
    • Up to 6500 screenshots saved;
    • Support periodic recording function;
    • Up to 3.9M/s USB high-speed transfer;
    • Customized international report generation.

    FUNCTIONS

    • Energy loss calculator: classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint true system energy losses in dollars (other local currencies available).
    • Power inverter efficiency: simultaneously measure AC output power for power electronics systems.
    • Power wave data capture: E6000 analyzers capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.).
    • Waveform capture: E6000 capture 50/60 cycles (50/60Hz) of each event that is detected in all modes, without set-up.
    • Automatic transient E6000 analyzers capture 200 kHz waveform data on all phases simultaneously up to 1000V.
    • Fully class-A compliant: E6000 analyzers conduct tests according to the stringent international IEC 61000-4-30 class-A standard.
    • Mains signaling: E6000 analyzer measure interference from ripple control signals at specific frequencies.
    • Troubleshoot: analyze the trends using the cursors and zoom tools.
    • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance.
    • Measure all three phases and neutral: with included four flexible current probes with enhanced thin flex designed to fit into the tightest places.
    • Automatic trending: every measurement is always automatically recorded, without any set-up.
    • System-monitor: ten power quality parameters on one screen according to EN50160 power quality standard.
    • Logger function: configure for any test condition with memory for up to 600 parameters at user defined intervals.
    • View graphs and generate reports: with included analysis software.
    • Battery life: up to 5 hours operating time per charge on Li-ion battery pack.

    PARAMETERS

    Electrical parameters 
    Voltagerms, ava, pk+, pk-, rms-1/2, CF
    FrequencyFreq
    Currentrms, ava, pk+, pk-, rms-1/2, CF
    Power & energyP, S, Q, PF, DPF, W
    ComputationTHD, DC, 1-50 Harm, 1-50 InHarm, 1-35 HiHarm, 1-50 SubHarm
    Voltage harmonicTHD, DC, 1-50 Harm, 0-49 InHarm, 1-35 HiHarm, 1-50 SubHarm , KF
    Current harmonicTHD, DC, 1-50 Harm
    Harmonic powerIa, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
    Fluctuation and flickeringPST, PLT, Fluct, Fluct Max
    UnbalV Pos, A pos , V neg , A neg , V zero, A zero, Unbal
    Event logVoltage swell, voltage sags, DIP, surge current, voltage and current distortion out of limit, odd harmonics containing rate out of limited, unbalanced voltage current out of limit, frequency out of limit, PST out of limit, PLT out of limit, long-term voltage interruption, voltage fluctuation deviation
    P, Q, S name 
    Measurement typesP: Calculate by every 10 cycles
    S: Calculated by the effective value of voltage and current
    Q: Calculated by the apparent power, active power
    DisplayTable charts, trend chart
    Measuring range/resolutionAccording to the range of the voltage and current
    measuring accuracy±0.5%
    Arms 
    Measurement modeCalculated by the square root value of 10 cycle
    Display modeEffective current value of each channel
    Measuring range/resolutionCurrent: according to the current clamps
    Option:5A/50A/100A/500A
    Current clamps: 1200A/3000A/6000A(Flexible Current Clamp)
    Accuracy0.1% + accuracy of the current clamps
    Frequency 
    Measurement modeCalculate by 10 cycles (50Hz) or (60Hz)
    Display modeMeasurement by 10 cycles
    Nominal frequency/resolution50.000Hz/0.001Hz or 60.000Hz/0.001Hz
    Bandwidth measurement42.5-57.5Hz or 52.5-67.5Hz
    Measurement accuracy±0.001Hz
    Half-wave RMS current/voltage 
    Measurement modeCalculate by every 2 cycles. Each cycle ,1/2 cycle made up of a waveform calculation
    Measuring range/resolutionVoltage: 120V/0.01V, 230V/0.01V, 400V/0.01V, 1000V/0.01V,Current: According to the current clamps
    measurement accuracy±0.1%
    Vrms 
    Measuring circuit1P2W/ 2P3W /3P3W/ 3P4W
    Basic frequency of the measuring circuit50Hz
    Input channels4 phase voltage, 4 phase current
    Measurement rangeVoltage measurement range: standard: 120V, 230V, 400V, 1000V, Max 1000V instantaneous voltage
    Current measurement range: according to the current clamps, only support the v signal output current clamp
    Power factor 
    Measurement modeThe ratio of average power to apparent power
    Display modeReal-time data showed
    Measurement range/resolution-1.000-1.000/0.001
    Measurement accuracy±1%
    Vfund, Afund, Harmonic power 
    Measurement modeMeet IEC61000-4-7,Analysis time window is ten cycles
    Window points5120 points
    Display modeForm figure, trend charts, histograms
    Number of measurement1-50 Times
    Measurement accuracyVfund >1%: Error<1%
    Vfund <1%: Error<0.05% Rated Voltage
    Afund >3%: Error<1%
    Afund <3%: Error<0.05% Current range
    InHarm Voltage, InHarm current 
    Measurement modeMeet IEC61000-4-7, Analysis time window is ten cycles
    Window points5120 points
    Display modeForm figure, trend charts, histograms
    Numbers of measurement1-16 groups
    Measurement accuracyVfund >1%: Error<1%
    Vfund <1%: Error<0.05% Rated Voltage
    Afund >3%: Error<1%
    Afund <3%: Error<0.05% Current range
    HiHarm Voltage, HiHarm current 
    Measurement modeMeet IEC61000-4-7, Analysis time window is ten cycles
    Window points5120 points every 10 cycles
    Display modeForm figure, trend charts, histograms
    Numbers of measurement1-35 groups
    Measurement accuracyVfund >1%: Error<1%
    Vfund <1%: Error<0.05% rated voltage
    Afund >3%: Error<1%
    Afund <3%: Error<0.05% current range
    Voltage SubHarm Current SubHarm 
    Measurement modeMeet IEC61000-4-7, analysis time window is ten cycles
    Window points5120 points every 10 cycles
    Display modeForm figure, trend charts, histograms
    Numbers of measurement1-50 groups
    Measurement accuracyVfund >1%: Error<1%
    Vfund <1%: Error<0.05% Rated Voltage
    Afund >3%: Error<1%
    Afund <3%: Error<0.05% Current range
    Voltage/current Unbal (pos, neg) 
    Measurement mode3P3W or 3P4W, using three phase of fundamental wave components to calculate
    Display modeForm figure, trend charts, histograms
    Measurement accuracyVoltage unbal: ±0.2%
    Current unbal: ±0.5%
    Voltage fluctuation 
    Measurement modeCalculate by the quadratic mean of half wave.
    Display modeForm figure, trend charts
    Measurement accuracy±1%
    IEC Flickering 
    MeasurementP short term (Pst) , P long term (Plt)
    Measurement modeAccording to IEC61000-4-15 Standard to calculate Pst (10 mins) Plt (2 hours)
    Display modeForm figure, trend charts
    Measurement range0-20
    Measurement accuracy±5%
    Surge current 
    Measurement modeHalf-wave RMS of current is higher than set value and sustain time is 10ms-1min
    Display modeMaximum of the surge current and surge current wave
    Measurement accuracy0.10%
    Voltage swell, Voltage sags, DIP 
    Measurement modeSwell: When half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as swell.
    Sags: When half-wave RMS of voltage is lower than set value and sustain time is 10ms-1min, judged as sags.
    DIP: half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as DIP
    Display modeSwell, sags, DIP wave sustain time, extent and so on.
    Measurement accuracy0.10%
    Machinery 
    Size263mm x 168mm x 65mm
    Weight2KG
    Power supply 
    Voltage input110V-240V
    Adapter output15V, 3A
    BatteryRechargeable nickel metal hydride, 4500mAh
    Battery working time4h
    Battery recharging time5h (Environment temperature 25°C)
    Power saving facilityLCD backlight brightness is adjustable, standby time is adjustable
    Display 
    Size112.8 x 84.6mm
    Color260000 color
    Resolutions640 x 480
    BrightnessMax 350 cd/m2 (Typ), brightness is adjustable
    Contrast500:1 (Typ)
    Visual angle70/70/50/70 (Typ.)(CR ≥10) ( Left/ Right/ UP/Down)
    Store 
    TypeTF card (inbuilt)
    Size8G
    Standards 
    Measurement methodIEC 61000-4-30
    Measurement performanceIEC 61000-4-30 A LVL
    FlickeringIEC 61000-4-15
    HarmonicIEC 61000-4-7
    Safety 
    StandardGB 4793.1-2007/IEC 61010-1:2001: "Measurement, control and laboratory electrical equipment safety requirements", first part: general requirements.
    Security level: CAT III 1000 V/ CAT IV 600 V.
    MAX voltage of phase angle inputCAT III 1000V/CAT IV 600V
    Environmental conditions 
    Working environment0°C to +45°C, humidity below 90rh%
    Storing environment-20°C to +50°C, humidity below 95rh% (non-condensing)

    Quality HANDHELD THREE PHASE POWER QUALITY ANALYZER WITH CLAMP ON CT for sale
    Send your message to this supplier
     
    *From:
    *To: Beijing GFUVE Electronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 portofva.com. All rights reserved.